ST-SLC-301020 Three-phase single-channel intelligent controller
ST-SLC-301020
Three-phase single-channel intelligent controller
Measurement accuracy≤2%; demand side remote control; overvoltage, undervoltage, overcurrent precise protection
consulting price
The price is subject to the contract
Product Manual
ST-SLC-301020 Three-phase single-channel intelligent controller instruction
Download
Consult now
Application scenarios
image is missing Factory
image is missing Office building
image is missing Hotel
Product Features
image is missing
Real-time measurement
embedded measurement unit, online monitoring of load and channel status, measurement accuracy≤2%
image is missing
Channel control
According to the instruction intelligent selection or manual button operation, the corresponding channel AC zero-crossing point can be turned on or off
image is missing
Communication interaction
Embedded with relevant modules, it can realize information interaction, remote control and networking of massive intelligent switches
image is missing
Program management
program according to the needs, complete the given work, or realize the sequence on and off control and program management control of a large number of loads through the communication system
image is missing
Power protection
protection setting Undervoltage: 0~300V (AC) (default 150V) setting - overvoltage: 0~300V (AC) (default 260V) setting - single channel overcurrent: 0~40A (AC) (default 40A)
Advantages
image is missing
AC zero-crossing, no arc ,Long lasting
image is missing
Leakage overload protection
safe and reliable
image is missing
Intelligent management and control
without on-site
Core Technology
image is missing
  1. Closing at voltage zero-crossing, no impact on the load, increasing the service life of the equipment
  2. Current zero-crossing point, no arc, no heat generation, saving energy consumption and eliminating hidden dangers of electricity safety
  3. No harmonic interference, zero radiation on start and stop
  4. Equipment-level safety and reliability, without overload protection devices, far exceeding relevant national and industry standards
Technical parameter
Product model ST-SLC-301020
Rated working voltage 220±15%V(AC)
Rated voltage 380V(AC)
Channel rated current 3*40A(AC)
Rated frequency 50Hz
Standby power consumption <2.7W
Voltage, current measurement accuracy ≦ 2%
1 input IO 5VDC, less than 5mA
Product Size
image is missing image is missing
Relevant certificates
image is missing image is missing
版权所有©1993-2022 广州三川控制系统工程设备有限公司 粤ICP备14009361号-1 粤公安网安备44011202000575 浏览次数:0
产品和系统
行业领域
资讯中心
三川智控™
在线实时演示
关注我们
wechatpng
toutiaopng
zhihupng
baidupng
售前客服:020-86361851
邮箱:service@suntrans.net
地址:广东省广州市黄埔区南云五路11号光正科技产业园内A-401
邮编:510700
版权所有©1993-2022 广州三川控制系统工程设备有限公司
浏览次数:0